Protect Pneumatic Equipment from Moisture!
- Energy-saving design (Second re-heater + Digital scroll compressor)
- Power consumption: Reduced by up to 76%
- Exhaust heat: Reduced by up to 25%
- Tolerant of high temperature environments!
- Ambient temperature: Up to 45°C, Inlet air temperature: Up to 60°C
Description
Refrigated Air Dryers Protec Pneumatic Equipment from Moisture! An air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail |
||
Malfunctioning of valves and actuators caused by dripping grease | Decomposition of auto drain caused by rusting inside pipes | Generation of water droplets |
![]() |
![]() |
![]() |
Tolerant of high temperature environment (ambient temperature 45°C), Energy Saving Design! Air cooled type can be used at ambient temperature 45°C second re-heater helps the heat radiation of the condenser allow use at ambient temperature 45°C |
||
![]() |
||
Energy saving design: Reduce Exhaust heat from air dryer by up to 25% Suppresses ambient temperature increase (air-cooled type)/ Reduces amount of facility water (water-cooled type)! second re-heater reduces the load to the condenser, and reduces exhaust heat from air dryer by up to 25%. (comparison with other SMC products) |
Air Compressor, Air Compressor Indonesia
Spesifikasi
Standard inlet air temperature type IDF...E Series |
![]() |
|||
Model |
Rated inlet condition |
Applicable air compressor [kW] |
Port Size |
IDF1E |
35°C 0.7 MPa |
0.75 |
Rc3/8 |
IDF2E |
1.5 |
||
IDF3E |
2.2 |
||
IDF4E |
3.7 |
Rc1/2 |
|
IDF6E |
5.5 |
Rc3/4 |
|
IDF8E |
7.5 |
||
IDF11E |
11 |
||
IDF15E1 |
15 |
Rc1 |
|
IDF22E |
22 |
R 1 |
|
IDF37E |
37 |
R1 1/2 |
|
IDF55E |
40°C 0.7 MPa |
55 |
R2 |
IDF75E |
75 |
The air dryers (CE or UL compliant) conforming to the international standards are separately available.
Standard inlet air temperature type IDF...F/D Series |
![]() |
|||
Model |
Rated inlet condition |
Applicable air compressor [kW] |
Port Size |
IDF100F |
40°C 0.7 MPa |
100 |
R2 |
IDF125F |
125 |
65 (2 1/2B) Flange |
|
IDF150F |
150 |
80 (3B) Flange
|
|
IDF190D |
190 |
||
IDF240D |
240 |
100 (4B) Flange |
|
IDF370D |
35°C 0.7 MPa |
370 |
150 (6B) Flange |
High inlet air temperature type IDU...E Series |
![]() |
|||
Model |
Rated inlet condition |
Applicable air compressor [kW] |
Port Size |
IDU3E |
55°C 0.7 MPa |
2.2 |
Rc3/8 |
IDU4E |
3.7 |
Rc1/2 |
|
IDU6E |
5.5 |
Rc3/4 |
|
IDU8E |
7.5 |
||
IDU11E |
11 |
||
IDU15E1 |
15 |
Rc1 |
|
IDU22E |
22 |
R1 |
|
IDU37E |
37 |
R1 1/2 |
|
IDU55E |
55 |
R2 |
|
IDU75E |
75 |